Fixed sorting electromagnet (RD)

Discover the fixed sorting electromagnet, a high-performance industrial solution for extracting ferrous metals and protecting conveyors.

In brief

  • The fixed sorting electromagnet (RD) is installed above a conveyor and extracts unwanted ferromagnetic particles from a material flow.
  • It is used in mining and quarrying, recycling, cement plants, foundries, food processing and the chemical industry.
  • It has an anodised aluminium coil embedded in epoxy resin, 4 suspension lugs and a 110 V or 220 V DC power supply.

Electromagnet, separation

  • Applications
  • Operating principles
  • Operating recommendations
  • General specifications
  • Case studies

Applications

Discover the fixed sorting electromagnet, a high-performance industrial solution for extracting ferromagnetic particles.

The fixed sorting electromagnet is designed to capture and extract unwanted ferromagnetic particles present in a moving material flow.

The fixed sorting electromagnet is used in

several sectors:

  • Mining and quarrying
  • Recycling and waste treatment industry
  • Cement plants and foundries
  • Food processing and chemical industry

Operating principles

Operating principle of our fixed sorting electromagnets**:**

  • The fixed sorting electromagnet is designed to capture and extract unwanted ferromagnetic particles present in a material flow.
  • Installed above a conveyor, it generates a strong magnetic field that attracts and retains metal contaminants.
  • Once separation is complete, de-energising the electromagnet releases the recovered metal particles.

Operating recommendations

Recommendations from our Lenoir-Mec experts:

  • Optimal positioning: Install the magnet at a suitable height for maximum efficiency according to the particle size of the product.
  • Regular cleaning: De-energise the magnet and manually remove the accumulated metal particles.
  • Checking the fastenings: Regularly inspect the condition of the suspension chains and supports to ensure stability.
  • Thermal monitoring: Use a temperature probe to prevent any overheating of the electromagnetic system.
  • Combination with a metal detector: To improve selectivity and limit energy consumption.

General specifications

Specifications of the Lenoir-Mec fixed sorting electromagnet:

  • Magnetic circuit in high-permeability steel
  • Anodised aluminium coil embedded in epoxy resin for greater durability
  • Secure suspension with 4 robust fixing lugs
  • Power supply: Available in 110V or 220V DC
  • Available as a permanent magnet (APRF) version

Advantages

  • Long attraction distance: Effective extraction capacity even at a large suspension height
  • Powerful electromagnet: suited to demanding industrial environments
  • Easy maintenance: Simplified cleaning by electrically de-energising the magnet

Services

  • Industrial commissioning assistance
  • Spare parts stock
  • Rapid after-sales service response
  • Installed base monitoring and periodic performance checks

Frequently asked questions

How does the RD fixed sorting electromagnet work?

Installed above a conveyor, it generates a strong magnetic field that attracts and retains ferromagnetic contaminants. De-energising the electromagnet then releases the recovered particles.

What materials is the RD electromagnet made of?

It has a magnetic circuit in high-permeability steel and an anodised aluminium coil embedded in epoxy resin for greater durability. The suspension is secured by 4 robust fixing lugs.

What power supply does the RD electromagnet require?

It is available with a 110 V or 220 V DC power supply. A permanent magnet version (APRF) is also available.

How should the RD electromagnet be cleaned and monitored?

To clean it, de-energise the magnet and manually remove the accumulated metal particles. A temperature probe prevents any overheating, and the condition of the suspension chains and supports must be checked regularly.

In which sectors is the fixed sorting electromagnet used?

It is used in mining and quarrying, recycling and waste treatment, cement plants and foundries, food processing and the chemical industry. Combining it with a metal detector improves selectivity and limits energy consumption.

Technical data

ModelDist. XWidth Cross-beltWidth In-lineElectromagnet AElectromagnet BPower (W)VoltageWeight (kg)
RD 8-1035080065078098034501101045
RD 8-123501000650780123044501101330
RD 8-163501400650780158062501101730
RD 10-124201000800990125054001101765
RD 10-144201200800990140060001102000
RD 10-164201400800990155065001102235
RD 10-184201600800990175072001102540
RD 12-14500120010001175143573001103175
RD 12-16500140010001175157578001103530
RD 12-18500160010001175177597001104000
RD 12-205001800100011751995102501104520
RD 14-15600130012001370147092002204160
RD 14-176001500120013701670112502204770
RD 14-196001700120013701870129502205370
RD 14-216001900120013702070135002205940
RD 14-236002100120013702280153002206575
RD 16-157201300140015801580103502205130
RD 16-177201500140015801720124002205880
RD 16-197201700140015801920143002206580
RD 16-217201900140015802120161002207280
RD 16-237202100140015802320182002207980
RD 16-257202300140015802520202502208680
RD 18-188301600160017801820159002206800
RD 18-218301900160017802120169002207955
RD 18-258302300160017802520180002209490

Advantages

  1. Long attraction distance: Effective extraction capacity even at a large suspension height
  2. Powerful electromagnet: suited to demanding industrial environments
  3. Easy maintenance: Simplified cleaning by electrically de-energising the magnet

To size your machine, have ready:

  • The material handled (type, particle size, moisture, temperature)
  • The throughput (t/h or m³/h) and bulk density
  • The conveying: belt width or chute section, speed, burden depth
  • The contaminants to remove (size and shape of ferrous or non-ferrous parts)
  • Site constraints: available space, ATEX zone, hygiene standards

A photo of the installation or a drawing is enough to start: attach it to your request. Unsure about a technical term? Magnetism glossary →

Request a quote

A project, a flow constraint? Our engineers size the right equipment for your installation.

Talk to an expert