TAP(N) permanent magnet magnetic drum
TAP(N) permanent magnet magnetic drum for ferromagnetic separation. Robust solutions for quarries, recycling and heavy industries.


In brief
- The TAP(N) permanent magnet magnetic drum automatically extracts ferromagnetic items from production lines.
- It is used in quarries, cement plants and recycling industries.
- It handles ferromagnetic items from 1 to 500 mm and runs 24/7 with no power consumption, in a Type A (agitator) or Type CC (crossed fields) version.
- Fields of application
- Operating principles
- Operating recommendations
- General characteristics
- Case studies
Fields of application


Why choose our TAP(N) permanent magnet magnetic drum?
The TAP(N) permanent magnet magnetic drum effectively protects your production lines and optimises the purity of your materials in:
- quarries
- cement plants
- recycling industries
This industrial magnetic drum automatically extracts ferromagnetic items from 1 to 500 mm, running 24/7 with no power consumption to prevent costly production stoppages and damage to downstream equipment.
Operating principles
This TAP(N) permanent magnet magnetic drum provides efficient magnetic separation on all types of granular flows and is fully suited to the constraints of heavy industrial installations. 3-step magnetic separation process:
- Instant attraction: The material flow is fed by conveyor onto the rotating drum. The permanent magnets instantly attract the ferromagnetic items, which adhere to the surface.
- Secured: The ferrous items are carried along the magnetic arc by the rotation of the drum.
- Automatic discharge: Beyond the magnetic influence zone, the ferrous items automatically drop off into a separate collection chute, while the non-magnetic materials continue along their natural trajectory.
Available magnetisation technologies
- Type A (Agitator): Alternating magnetic fields create a tumbling effect to release trapped particles.
- Type CC (Crossed Fields): Crossing magnetic fluxes to handle heavy pieces and ensure uniform cleaning of the material to be processed.
Operating recommendations
Recommendations from our Lenoir-Mec experts for your TAP(N) permanent magnet magnetic drum:
- Strategic positioning: Position the magnetic drum with a drop height limited to 500 mm and a feed point no more than 100-150 mm from the surface to ensure optimal attraction of fine particles.
- Precise calibration: Carry out an adjustment with reference ferromagnetic samples to define the optimal magnet position according to the particle size of your materials.
- Preventive maintenance: Check the surface condition of the drum, clean off magnetic build-up and inspect the anti-abrasion linings
General characteristics
Technical specifications of the TAP(N) magnetic drum
- High-performance magnetisation: Ferrite magnets (low flux density) for standard applications or neodymium magnets (high flux density) for fine and weakly magnetic particles, resistant to harsh industrial environments.
- Precision adjustment: Adjustable magnet positioning for optimised discharge according to the application, allowing adaptation to different material particle sizes.
- Robust geared motor: Through-shaft drive with integrated anti-rotation system, designed for continuous industrial operating conditions.
- Simplified maintenance: Easy access for cleaning and servicing, interchangeable coils and no critical wear parts.
Specialised technical options
- Anti-abrasion lining Métaline (2 mm) or rubber (6 mm) for aggressive materials
- ATEX 22 Ex II 3D certification for explosive atmospheres
- High-temperature version (>120°C) with specially treated magnets
- Stainless steel side guides 3 mm for precise flow guidance
Advantages
- Proven magnetic performance
- Robust, durable design ensuring a long service life
- Minimal maintenance: Simple, reliable system reducing interventions and operating costs
Services
- Industrial commissioning assistance
- Spare parts stock
- Installed base monitoring and periodic performance checks
- Rapid after-sales service response
Frequently asked questions
What applications is the TAP(N) magnetic drum designed for?
It protects production lines and optimises material purity in quarries, cement plants and recycling industries. It automatically extracts ferromagnetic items from 1 to 500 mm, 24/7 and with no power consumption.
How does the TAP(N) work?
The flow arrives by conveyor on the rotating drum and the permanent magnets attract the ferromagnetic items, which are carried along the magnetic arc. Beyond the magnetic influence zone, they drop off into a separate chute, while the non-magnetic materials follow their trajectory.
What magnetisation technologies are available on the TAP(N)?
Type A (Agitator) creates a tumbling effect using alternating magnetic fields to release trapped particles. Type CC (Crossed Fields) crosses the magnetic fluxes to handle heavy pieces with uniform cleaning. The magnets are ferrite, or neodymium for fine and weakly magnetic particles.
What options does the TAP(N) offer?
The options are a Métaline (2 mm) or rubber (6 mm) anti-abrasion lining, ATEX 22 Ex II 3D certification, a high-temperature version (above 120°C) and 3 mm stainless steel side guides.
How should the TAP(N) be positioned and maintained?
The drop height must be limited to 500 mm and the feed point placed no more than 100-150 mm from the surface. Maintenance consists of checking the surface condition of the drum, cleaning off magnetic build-up and inspecting the anti-abrasion linings.
Technical data
| Diameter Ø (mm) | Motor (kW) | Speed (rpm) |
|---|---|---|
| 204 (série 20) | 0,25 / 0,37 | 40 |
| 323,9 (série 31) | 0,25 / 0,37 | 35 |
| 406,4 (série 40) | 0,37 / 0,55 | 35 |
| 508 (série 50) | 0,55 / 0,75 | 30 |
| 609,6 (série 63) | 0,75 / 1,1 | 25 |
| Reference | Flow rate (m³/h) | Weight (kg) | Active width L (mm) |
|---|---|---|---|
| TAP(N) 20/25 | 4 | 30 | 250 |
| TAP(N) 20/36 | 5 | 42 | 365 |
| TAP(N) 20/41 | 6 | 48 | 415 |
| TAP(N) 20/46 | 7 | 55 | 465 |
| TAP(N) 20/56 | 8,5 | 61 | 565 |
| TAP(N) 20/61 | 10 | 73 | 615 |
| TAP(N) 20/71 | 11,5 | 86 | 715 |
| TAP(N) 20/86 | 13 | 99 | 865 |
| TAP(N) 20/101 | 14,5 | 113 | 1015 |
| TAP(N) 20/116 | 18,5 | 137 | 1165 |
| TAP(N) 31/36 | 19 | 80 | 365 |
| TAP(N) 31/41 | 22 | 85 | 415 |
| TAP(N) 31/46 | 24 | 90 | 465 |
| TAP(N) 31/56 | 30 | 101 | 565 |
| TAP(N) 31/61 | 32 | 106 | 615 |
| TAP(N) 31/71 | 37 | 117 | 715 |
| TAP(N) 31/86 | 45 | 133 | 865 |
| TAP(N) 31/101 | 53 | 148 | 1015 |
| TAP(N) 31/116 | 60 | 164 | 1165 |
| TAP(N) 40/36 | 34 | 104 | 365 |
| TAP(N) 40/41 | 40 | 111 | 415 |
| TAP(N) 40/46 | 43 | 117 | 465 |
| TAP(N) 40/56 | 50 | 131 | 565 |
| TAP(N) 40/61 | 57 | 137 | 615 |
| TAP(N) 40/71 | 66 | 150 | 715 |
| TAP(N) 40/86 | 80 | 170 | 865 |
| TAP(N) 40/101 | 94 | 190 | 1015 |
| TAP(N) 40/116 | 108 | 210 | 1165 |
| TAP(N) 50/46 | 66 | 154 | 465 |
| TAP(N) 50/56 | 80 | 170 | 565 |
| TAP(N) 50/61 | 88 | 190 | 615 |
| TAP(N) 50/71 | 100 | 217 | 715 |
| TAP(N) 50/86 | 122 | 254 | 865 |
| TAP(N) 50/101 | 144 | 282 | 1015 |
| TAP(N) 50/116 | 165 | 323 | 1165 |
| TAP(N) 50/136 | 195 | 367 | 1365 |
| TAP(N) 50/146 | 208 | 394 | 1465 |
| TAP(N) 50/166 | 238 | 425 | 1665 |
| TAP(N) 63/61 | 110 | 301 | 615 |
| TAP(N) 63/71 | 127 | 351 | 715 |
| TAP(N) 63/86 | 154 | 412 | 865 |
| TAP(N) 63/101 | 180 | 457 | 1015 |
| TAP(N) 63/116 | 208 | 525 | 1165 |
| TAP(N) 63/136 | 240 | 605 | 1365 |
| TAP(N) 63/146 | 260 | 629 | 1465 |
| TAP(N) 63/166 | 400 | 759 | 1665 |
| TAP(N) 63/186 | 440 | 905 | 1865 |
Advantages
- Proven magnetic performance
- Robust, durable design ensuring a long service life
- Minimal maintenance: Simple, reliable system reducing interventions and operating costs
To size your machine, have ready:
- The material handled (type, particle size, moisture, temperature)
- The throughput (t/h or m³/h) and bulk density
- The conveying: belt width or chute section, speed, burden depth
- The contaminants to remove (size and shape of ferrous or non-ferrous parts)
- Site constraints: available space, ATEX zone, hygiene standards
A photo of the installation or a drawing is enough to start: attach it to your request. Unsure about a technical term? Magnetism glossary →
Request a quoteA project, a flow constraint? Our engineers size the right equipment for your installation.
Talk to an expert